Show simple item record

dc.contributor.advisorGuillén Aparicio, Daniel
dc.contributor.authorRivera Molina, David José
dc.creatorRIVERA MOLINA, DAVID JOSE; 711811
dc.date.accessioned2023-08-05T15:31:53Z
dc.date.available2023-08-05T15:31:53Z
dc.date.issued2022-06-15
dc.identifier.citationRivera Molina, D.J. (2022). Data-driven control of voltage source converters for AC/DC power grids (Tesis doctoral). Instituto Tecnológico y de Estudios Superiores de Monterrey. Recuperado de: https://hdl.handle.net/11285/651077es_MX
dc.identifier.urihttps://hdl.handle.net/11285/651077
dc.descriptionhttps://orcid.org/0000-0001-9569-9691es_MX
dc.description.abstractThe use of Voltage Source Converters (VSC) is gaining ground in recent yearsmdue to the many benefits it offers. A wide range of electronic devices are using thisntechnology, including systems like renewable energy sources (RES), direct current transmission, Flexible AC transmission system (FACTS), are some of which can be mentioned. The energy matrixes of the countries around the world are changing and the electrical power systems are experiencing new challenges in control, dispatch, design, etc. This thesis involves the design of a new type of controller for VSC. This new controller is based on data gathered from the simulation of multiple setpoints of operations of a model-based control used for a VSC connected to the grid. Before the design of this new data-driven control, an model-based controller is modelled and tuned according to grid parameters and dynamic characteristics. The design of the new controller starts from the data obtained from the previous simulations of the model-based controller. The data is used as input to the control design which is based on the measured variables (time-discrete data). The control design follows many particular criteria defined by the control theory and can be solved by an optimization approach in order to comply with the stability function. The new controller must meet certain parameters such as robustness, speed, stability criterion, and capturing the grid dynamic characteristics within itself. The tests to compare the performance between the data-driven controller and model-based controller consist of using three types of devices that are VSC-based. These tests include step response, voltage recovery under transient conditions due to fault and load shedding. With these comparisons, the perks and disadvantages of using the new control approach were presented and proven using a two-area, four generator electric power system.es_MX
dc.format.mediumTextoes_MX
dc.language.isoenges_MX
dc.publisherInstituto Tecnológico y de Estudios Superiores de Monterreyes_MX
dc.relation.isFormatOfpublishedVersiones_MX
dc.relation.isreferencedbyREPOSITORIO NACIONAL CONACYT
dc.rightsopenAccesses_MX
dc.rights.urihttp://creativecommons.org/licenses/by/4.0es_MX
dc.subject.classificationINGENIERÍA Y TECNOLOGÍA::CIENCIAS TECNOLÓGICAS::INGENIERÍA Y TECNOLOGÍA ELÉCTRICAS::OTRASes_MX
dc.subject.lcshSciencees_MX
dc.titleData-driven control of voltage source converters for AC/DC power gridses_MX
dc.typeTesis Doctorado / doctoral Thesises_MX
dc.contributor.departmentEscuela de Ingeniería y Cienciases_MX
dc.contributor.committeememberLlamas Terres, Armando
dc.contributor.committeememberFederico Viramontes, Brown
dc.contributor.committeememberValdez Resendiz, Jesús E.
dc.contributor.mentorMayo Maldonado, Jonathan C.
dc.subject.keywordVSCes_MX
dc.subject.keywordPower converterses_MX
dc.subject.keywordStatcomes_MX
dc.subject.keywordHVDCes_MX
dc.subject.keywordControles_MX
dc.subject.keywordData-driven controles_MX
dc.contributor.institutionCampus Monterreyes_MX
dc.contributor.catalogeremijzarate, emipsanchezes_MX
dc.description.degreeDoctorado en Ciencias de Ingenieríaes_MX
dc.audience.educationlevelInvestigadores/Researcherses_MX
dc.identificator7||33||3306||330699es_MX


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

openAccess
Except where otherwise noted, this item's license is described as openAccess